+966-533428898

    IP Cameras

    Sourced and supplied across Saudi Arabia

    Resolution is the wrong number to specify a camera with. What matters is pixel density at the target — pixels per metre across the scene — and the DORI levels in IEC 62676-4 put figures on it: roughly 25 pixels per metre to detect that something is there, 62.5 to observe, 125 to recognise someone already known, and 250 to identify a stranger from the image alone. A high-resolution camera covering a wide car park may deliver detection and nothing more, and the footage is useless in exactly the situation it was bought for. Work backwards: decide what each camera must achieve, at what distance, and the lens and sensor follow. Two conditions here make the rest harder than the brochure suggests. Extreme contrast between shaded and sunlit areas needs genuine wide dynamic range, and a camera in a sealed housing in direct sun runs hot, so the mounting position and any sun shroud belong in the design.

    What to state in your enquiry

    The more of this you send, the closer the first quotation lands.

    Operational requirementDetect, observe, recognise or identify — per camera
    Target distance and scene widthWith the DORI level, this fixes the pixel density needed
    LensFixed or varifocal, and the field of view required
    Lighting conditionsShaded to sunlit contrast, and night-time illumination
    Wide dynamic rangeNeeded where a doorway is dark against bright ground outside
    Infrared illuminationBuilt-in or separate, and the range required
    Housing and sun exposureDirect sun heats a sealed housing — state the position
    IP and impact ratingDust ingress and vandal resistance at the mounting point
    PowerPoE class, and the budget available on the switch
    Bandwidth and codecCodec, bitrate and frame rate — they size the network and storage
    AnalyticsLine crossing, loitering, plate or face — state what is actually used
    Recording systemThe NVR or VMS these must be compatible with
    CybersecurityFirmware update policy and any procurement restriction that applies

    Standards we supply against

    • IEC 62676-4
    • IEC 60529

    Which type do you need?

    Select one and it travels with your enquiry. Not sure? Leave it and describe the application instead.

    We source to specification. Send your requirement and we will come back with options, lead time and pricing.