    Water Filtration Systems

    Sourced and supplied across Saudi Arabia

    Nothing here can be selected without a water analysis, and that is the single most useful thing to send with an enquiry. A treatment train is assembled backwards from the quality the process needs, and each stage exists to protect the next one: sediment filtration takes the load off the carbon, carbon protects a reverse osmosis membrane from the chlorine that would destroy it, and softening or antiscalant dosing keeps hardness from precipitating on the membrane surface. In this region the feed is usually hard and high in dissolved solids, which does two things — it makes RO the workhorse for anything demanding, and it makes recovery rate a real design decision, because the higher the fraction of feed you turn into product, the more concentrated the reject becomes and the faster the membranes scale. Say what the treated water is for, what the source is, and what happens to the reject stream, because reject disposal is often the harder half of the problem.

    What to state in your enquiry

    The more of this you send, the closer the first quotation lands.

    Feed water analysisTDS, hardness, chloride, silica, iron, turbidity, and chlorine
    Feed sourceMunicipal, borehole, tanker, brackish or seawater
    Required product qualityWhat the treated water must achieve, and for what use
    Product flowRequired treated flow, and the daily volume
    Recovery rateProduct as a fraction of feed — it drives scaling and reject volume
    Reject disposalWhere the concentrate goes — often the harder half of the problem
    Treatment stagesSediment, carbon, softener, antiscalant dosing, RO, UV, remineralisation
    PretreatmentChlorine must be removed before an RO membrane
    Storage and repressurisationProduct tank volume and the delivery pressure needed
    Potable approvalState if potable approval is required on wetted components
    Skid or loose supplyPackaged skid, or components for site assembly
    ConsumablesCartridge, media and membrane replacement interval and supply
    Control and monitoringConductivity monitoring, alarms and any remote reporting

    Standards we supply against

    • NSF/ANSI 61
    • NSF/ANSI 58

    Which type do you need?

    Select one and it travels with your enquiry. Not sure? Leave it and describe the application instead.

    We source to specification. Send your requirement and we will come back with options, lead time and pricing.