    Sourced and supplied across Saudi Arabia

    Low-voltage cable is sized on paper and fails in the ground. IEC 60502-1 current ratings are published against reference conditions — a stated ambient, a stated soil thermal resistivity, one circuit on its own — and none of those describe a duct bank in Dammam in August carrying six circuits through sand that has dried to a poor conductor of heat. Derating for ambient, for grouping and for soil resistivity routinely takes a cable two sizes up from the figure a table first suggests, and a cable that runs warm does not fail immediately; it ages its insulation quietly and fails in year seven. The other decision that belongs in the enquiry is fire performance, because a cable that will run through an occupied building or an escape route is specified against flame propagation, halogen emission and smoke density, and those are separate requirements from the current rating. Send the route, the installation method and the load.

    What to state in your enquiry

    The more of this you send, the closer the first quotation lands.

    Voltage rating600/1000 V is the usual LV designation
    Conductor materialCopper or aluminium — affects size, weight and termination
    Cross-section and coresSquare millimetres, core count, and whether a neutral is reduced
    Insulation and sheathXLPE or PVC insulation, PVC or LSZH outer sheath
    Installation methodDirect buried, in duct, on tray, in air, or in a trench
    GroupingCircuits sharing the route — this derates every one of them
    Ground and air temperatureState the design maxima, not the annual average
    Soil thermal resistivityDry sand carries heat poorly and derates buried runs sharply
    Fire performanceFlame propagation, halogen-free and low smoke where required
    ArmourState if mechanical protection or an armour earth path is needed
    Route lengthDrives volt drop, which often decides the size before current does
    Drum lengthsContinuous lengths required, and any joint restriction
    CertificationTest certificates and any approved vendor list that applies

    Standards we supply against

    • IEC 60502-1
    • IEC 60228
    • IEC 60332-1-2
    • IEC 60754-1
    • IEC 61034-2

    Which type do you need?

    Select one and it travels with your enquiry. Not sure? Leave it and describe the application instead.

    We source to specification. Send your requirement and we will come back with options, lead time and pricing.